Category | Product name | Features(Highlights) | Standard |
EMP test system | Bounded wave EMP test system | - ●The generator can be moved to facilitate
- debugging and replacement.
- ●Remote control.
- ●Centralized load design is adopted for
- terminal load.
| MIL-STD-464 |
Radiation wave EMP test system | - ●Professional standard test training and
- value-added services of system
- reinforcement design.
- ●Fully automated standard testing of the
- whole process.
- ●The test system can be customized.
- ●Margin of safety test can be performed.
|
PCI test system |
CW irradiation test system |
Mobile EMP test system |
MIL-STD-461 test system | CE101 test system | - ●Combined with EMC facilities, the
- background noise is low, which is far
- better than the margin index required
- by the standard.
- ●Compatible with the global major power
- supply types.
| All tests conform to MIL-STD-461 standard |
CE102 test system |
RE101 test system |
RE102 test system |
CE106 test system | - ●Tests covering transmitters, amplifiers
- and receivers.
- ●Customization service for special filter of
- EUT.
|
RE103 test system | ●Customization service for special filter of EUT |
CS101 test system | - ●The high sensitivity precise voltage sensor
- technology is used to solve the problem
- of AC base wave.
- ●Wide dynamic range and wide voltage
- range technology (measuring voltage is
- from 1mV, to 1000V).
- ●Compatible with RTCA DO-16. Chapter
- 18.
|
CS103 test system | - ●Efficient compliance verification test
- program.
- ●Precise evaluative test program.
|
CS104 test system |
CS105 test system |
CS114 test system | - ●Wide test frequency range: 2kHz~400
- MHz, covering the standard test
- requirements. (especially for low
- frequency test of EUT of solid state
- power supply on
- ship or submarine)
- ●High security: automatic system fault
- monitoring, automatic fault protection.
|
CS115 test system | ●Actual induced current monitoring technology. |
CS116 test system |
RS103 test system | - ●Wide test frequency range: 10kHz ~
- 40GHz, filed strength 200V/m.
- ●High accuracy: Multi-probe application,
- automated testing.
- ●High security: automatic system fault
- monitoring, automatic fault protection.
|
RS105 test system | ●The field strength is continuously adjustable. |
CE107 test system | ●Product features meet standards. |
CS117 test system |
CS118 test system |
RS101 test system |
CS102 test system |
CS106 test system |
CS109 test system |
CS112 test system |
EMC test facility | Semi-anechoic chamber | - ●Low background noise, much better than
- the minimum level required by MIL-STD
- -461G standard.
- ●Frequency range: 9kHz~40GHz
- (optional: 50GHz), shielded efficiency
- is better than the requirements of
- EN 50147-1.
| MIL-STD-461G |
Electromagnetic shielded chamber | - ●Low background noise, much better than
- the minimum level required by MIL-
- STD-461G standard.
- ●Frequency range: 9kHz~18GHz (optional:
- 40GHz), shielded efficiency is better
- than the requirements of EN 50147-1.
|
Reverberation chamber | - ●Frequency range: 200MHz~18GHz
- (optional: 40GHz).
- ●The reverberation chamber size and
- internal configuration can be
- customized.
|
Electromagnetic shielded vehicle | - ●Mobile shielding test vehicle.
- ●Frequency range: 9kHz~18GHz
- (optional: 40GHz)
- ●The size and internal configuration of the
- mobile electromagnetic shielded
- vehiclecan be customized.
|
Open area test site (OATS) | - ●The size and configuration of the OATS
- can be customized (such as turntable,
- reflective floor, etc.).
|
HPM test system | HPM threat level irradiation test system | - ●Professional standard test training and
- value-added service of system
- reinforcement design.
- ●Fully automated standard testing of the
- whole process.
- ●The test system can be customized.
- ●Safety margin test can be performed.
| MIL-STD-464 MIL-STD-464 |
HPM irradiation equivalent test system |
HPM injection equivalent test system |
Mobile HPM test system |
External RF EME test system | RF EME full level irradiation test system | - ●Test frequency range: 10kHz ~ 45GHz
- ●Professional standard test training and
- value-added service of system
- reinforcement design.
- ●Safety margin test can be performed.
|
Lightning test system | Lightning direct effect test system | - ●Fully automated standard testing of the
- whole process.
- ●Professional standard test training and
- value-added service of system
- reinforcement design.
- ●Safety margin test can be performed.
|
Lightning direct effect test system |
Electrostatic charge control test system | Human electrostatic test system | - ●Discharge voltage: ±0.2kV~±30kV
- ●Professional standard test training and
- value-added service of system
- reinforcement design.
- ●Safety margin test can be performed.
|
| Precipitation static test system | - ●Discharge voltage: ±50kV~±300kV
- ●Maximum discharge current: 10mA
- ●Professional standard test training and
- value-added service of system
- reinforcement design.
- ●Safety margin test can be performed.
|
300kV electrostatic test system | - ●Discharge voltage: ±50kV~±300kV
- ●Professional standard test training and
- value-added service of system
- reinforcement design.
- ●Safety margin test can be performed.
|
Emission control(EMCON)test system | Emission control(EMCON) test system | - ●Test frequency range: 500kHz~40GHz
- ●Low noise floor test system.
- ●Fully automated standard testing of the
- whole process.
- ●The mobile EMCON test system can be
- customized (used for site test, and the
- electromagnetic background of the site
- will be evaluated before the test).
- ●Professional standard test training.
|
Other electromagnetic compatibility testing system and equipment | Magnetic field test, Electric field test, Antenna port interference voltage test, etc. | - ●Fully automated standard testing of the
- whole process.
- ●Professional standard test training .
- ●The test system can be customized.
|